Hawk Pumps - Other Pumps.
Peripheral Pumps
TECHNICAL DATA
- Peripheral edge of the impeller contains numerous radial blades
- Designed to yield energy to the fluid being pumped
- Non-pulsation flow
| Peripheral Pumps |
| Model |
Maximum Pressure |
Minimum Flow |
Motor |
| EV10/16 |
16 Bar |
15 L/min |
2,2 kW |
APPLICATIONS
- Cooling chicken houses
- Booster pump for high buildings
- Washdown pumping system
Centrifugal Pumps
TECHNICAL DATA
- Peripheral edge of the impeller contains numerous radial blades
- Designed to yield energy to the fluid being pumped
- Non-pulsation flow
APPLICATIONS
- Handling clean water not containing abrasive particles and fluids
- Domestic applications
- Automatic distribution of water from surge tanks
- Watering gardens
- Boosting insufficient mains water pressure
| Centrifugal Pumps |
| Model |
Kw |
Flow Rate |
|
| m³/h |
0,0 |
0,3 |
0,6 |
0,9 |
1,2 |
1,5 |
1,8 |
2,1 |
2,4 |
3,0 |
3,6 |
4,2 |
4,8 |
| L/min |
0 |
5 |
10 |
15 |
20 |
25 |
30 |
35 |
40 |
50 |
60 |
70 |
80 |
| PK60 |
0,37 |
Total Dynamic Head In Meters |
40 |
38 |
33,5 |
29 |
824 |
19,5 |
15 |
10 |
5 |
|
|
|
|
| PK65 |
0,5 |
55 |
50 |
45,5 |
40,5 |
36 |
31 |
27 |
22 |
17 |
8 |
|
|
|
| PK70 |
0,6 |
65 |
62 |
57 |
52 |
47 |
42 |
37 |
32 |
27 |
18 |
|
|
|
| PK80 |
0,75 |
70 |
66 |
61 |
56 |
51 |
46 |
41 |
36,5 |
31 |
22 |
|
|
|
| PK90 |
0,75 |
90 |
82 |
71 |
60 |
49 |
38 |
27 |
17 |
5 |
|
|
|
|
| PK100 |
1,1 |
85 |
80 |
75 |
70 |
65 |
60 |
55 |
50 |
45 |
35 |
25 |
15 |
|
| PK200 |
1,5 |
90 |
86 |
81 |
76 |
71 |
65,5 |
60 |
55 |
50 |
40 |
30 |
20 |
10 |
| 380 volt versions available on request |
|
 |